Be Gutter Problem Aware
Problem Common Causes
noisy drip in pipe thin metal
leak behind gutter no flashing or short/damaged overhang
hangars come loose no expansion fittings or gutter incorectly placed in joints or weak substrate
bowing hangars too tight or too far between mounts or no expansion fittings or gutter incorrect in joint or hangars not in line
leaks at joint incorrect adhesive or sealant or process or damaged joint seals (expansion allowance problems?)
corrosion pollutants/salts or gutter not kept clean and dry (proper drain slope) improper coating or flat bottom
debris catches at joints gutter joints are not solvent welded or soldered or other lap type with lap below flow.
knocked off in snow gutter edge not below fall line or hangars too weak or far apart
knocked off by ice or mud hangars too weak or too far apart or not on strong substrate
discoloring in white a formulation problem in dark colors U.V. and time
overflow too few or too small downspouts or clogging joints or wrong slope or gutter too small (just too much rain)
parts fall off not solvent welded or soldered or sealed and riveted
clogging pipe pipe too small
clogging elbow or pipe joint elbow too small or too close to level or female end on top
return to raingutter.com